提交 fe87bef0 编写于 作者: H Heiner Kallweit 提交者: David S. Miller

r8169: don't check WoL when powering down PHY and interface is down

We can power down the PHY irregardless of WOL settings if interface
is down. So far we would have left the PHY enabled if WOL options
are set and the interface is brought down.
Signed-off-by: NHeiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 433f9d0d
......@@ -4635,7 +4635,7 @@ static void rtl_wol_suspend_quirk(struct rtl8169_private *tp)
static bool rtl_wol_pll_power_down(struct rtl8169_private *tp)
{
if (!tp->saved_wolopts)
if (!netif_running(tp->dev) || !tp->saved_wolopts)
return false;
rtl_speed_down(tp);
......